FLIR GF304 / GF306 / GF320 / GF346 Technical Specifications
| GF304 | GF306 | GF320 | GF346 | |
| Imaging and optical data | ||||
| Focal Plane Array (FPA) / Spectral range | Cooled QWIP / 8.0–8.6 µm | Cooled QWIP / 10.3–10.7 µm | Cooled InSb / 3.2–3.4 µm | Cooled InSb / Built-in cold band pass filter 4.52 - 4.67 µm |
| Measurement | ||||
| Accuracy | ±1°C for temperature range (0-100 °C) or ±2% of reading for temperature range (> +100 °C) | ±1°C for temperature range (0-100 °C) or ±2% of reading for temperature range (> +100 °C) | ±1°C for temperature range (0-100 °C) or ±2% of reading for temperature range (> +100 °C) | +/- 1 ºC or +/- 1% of reading for temperature range 0º C to +300 ºC |
| Measurement range | -20ºC to +500ºC | -40ºC to +500ºC | -40ºC to +350ºC | -20ºC to +300ºC |
| Power system | ||||
| Battery operating time | > 3 hours at 25°C and typical use | > 2 hours at 25°C and typical use | > 3 hours at 25°C and typical use | > 3 hours at 25°C and typical use |
| Start-up time | Typically 8 min. @ 25°C | Typically 10 min. @ 25°C | Typically 7 min. @ 25°C | Typically 7 min. @ 25°C |
| Environmental data | ||||
| Operating temperature range | –20°C to +40°C | –20°C to +40°C | –20°C to +50°C | –20°C to +50°C |
| Gas detection | ||||
| Gases | • R404A • R407C • R410A • R134A • R417A • R422A • R507A • R143A • R125 • R245fa |
• Sulfur Hexafluoride (SF6) • Acetyl Chloride • Acetic Acid • Allyl Bromide • Allyl Chloride • Allyl Fluoride • Ammonia (NH3) • Bromomethane • Chloride Dioxide • Ethyl Cyanoacrylate • Ethylene • Furan • Hydrazine • Methylsilane • Methyl Ethyl Ketone • Methyl Vinyl Ketone • Propenal • Propene • Tetrahydrofuran • Trichloroethylene • Uranyl Fluoride • Vinyl Chloride • Vinyl Cyanide • Vinyl Ether |
• Benzene • Ethanol • Ethylbenzene • Heptane • Hexane • Isoprene • Methanol • MEK • MIBK • Octane • Pentane • 1-Pentene • Toluene • Xylene • Butane • Ethane • Methane • Propane • Ethylene • Propylene |
• Acetonitrile • Acetyl cyanide • Arsine • Bromine isocyanate • Butyl isocyanide • Carbon monoxide • Chlorine isocyanate • Chlorodimethylsilane • Cyanogen bromide • Dichloromethylsilane • Ethenone • Ethyl thiocyanate • Germane • Hexyl isocyanide • Ketene • Methyl thiocyanate • Nitrous oxide • Silane |
| Imaging and optical data | |
| Field of view (FOV) / Minimum focus distance | 14.5º lens: 14.5º x 10.8º / 0.5m 24º lens: 24° × 18° / 0.3 m |
| F-number | 1.5 |
| Focus | Automatic (one touch) or manual (electric or on the lens) |
| Zoom | 1–8× continuous, digital zoom |
| Digital image enhancement | Noise reduction filter, High Sensitivity Mode (HSM) |
| IR resolution | 320 × 240 pixels |
| Thermal sensitivity / NETD | <15 mK @ +30°C |
| Sensor cooling | Stirling Microcooler (FLIR MC-3) |
| Electronics and data rate | |
| Full frame rate | 60 Hz |
| Image presentation | |
| Display | Built-in widescreen, 4.3 in. LCD, 800 × 480 pixels |
| Viewfinder | Built-in, tiltable OLED, 800 × 480 pixels |
| Automatic image adjustment | Continuous/manual; linear or histogram based |
| Manual image adjustment | Level/span |
| Image modes | IR-image, visual image, High Sensitivity Mode (HSM) |
| Measurement analysis | |
| Spotmeter | 10 |
| Area | 5 boxes with max./min./average |
| Profile | 1 live line (horizontal or vertical) |
| Difference temperature | Delta temperature between measurement functions or reference temperature |
| Reference temperature | Manually set or captured from any measurement function |
| Emissivity correction | Variable from 0.01 to 1.0 or selected from editable materials list |
| Measurement corrections | Reflected temperature, distance, atmospheric transmission, humidity, external optics |
| Set-up | |
| Menu commands | Level, span Auto adjust continuous/manual/semi-automatic Zoom Palette Start/stop recording Store image Playback/recall image |
| Color palettes | Iron, Gray, Rainbow, Arctic, Lava, Rainbow HC |
| Set-up commands | 1 programmable button, overlay recording mode, local adaptation of units, language, date and time formats |
| Storage of images | |
| Image storage type | Removable SD or SDHC Memory Card, two card slots |
| Image storage capacity | > 1200 images (JPEG) with post process capability per GB on memory card |
| Image storage mode | IR/visual images Visual image can automatically be associated with corresponding IR image |
| Periodic image storage | Every 10 seconds up to 24 hours |
| File formats | Standard JPEG, 14 bit measurement data included |
| GPS | Location data automatically added to every image from built-in GPS |
| Video recording and streaming | |
| Non radiometric IR-video recording | MPEG4 (up to 60 minutes/clip) to memory card. Visual image can automatically be associated with corresponding recording of non radiometric IR-video. |
| Visual video recording | MPEG4 (25 minutes/clip) to memory card |
| Radiometric IR-video streaming | Full dynamic to PC using USB or WLAN |
| Non radiometric IR-video streaming | RTP/MPEG4 |
| Visual video streaming | MPEG4 using Wi-Fi Uncompressed colorized video using USB |
| Digital camera | |
| Built-in digital camera | 3.2 Mpixel, auto focus, and two video lamps |
| Laser pointer | |
| Laser | Activated by dedicated button |
| Data communication interfaces | |
| WLAN | Peer to peer (adhoc) for iOS or infrastructure (network) for Android |
| USB | USB-A: Connect external USB device (e.g. memory stick) USB Mini-B: Data transfer to and from PC |
| USB, standard | USB Mini-B: 2.0 High Speed |
| Video | Digital Video Output (image) |
| Power system | |
| Battery type | Rechargeable Li Ion battery |
| Battery voltage | 7.2 V |
| Charging system | In camera (AC adapter or 12 V from a vehicle) or 2-bay charger |
| Environmental data | |
| Storage temperature range | –30°C to +60°C |
| Humidity (operating and storage) | IEC 68-2-30/24 h 95% relative humidity +25°C to +40°C (2 cycl) |
| EMC | EN61000-6-4 (Emission) EN61000-6-2 (Immunity) FCC 47 CFR Part 15 class A (Emission) EN 61 000-4-8, L5 |
| Encapsulation | IP 54 (IEC 60529) |
| Bump | 25 g (IEC 60068-2-29) |
| Vibration | 2 g (IEC 60068-2-6) |
| Physical data | |
| Camera weight, incl. lens and battery | 2.48 kg |
| Battery weight | 0.24 kg |
| Cameras size, incl. lens (L × W × H) | 306 × 169 × 161 mm |
| Tripod mounting | Standard, ¼"-20 |
| Housing material | Aluminium, Magnesium |
| Grip material | TPE Thermoplastic Elastomers |
| Scope of delivery | |
| Thermal imaging camera, Hard transport case, Battery charger, Battery, 2 ea., Calibration Certificate, Downloads brochure, FLIR Tools PC software CD-ROM, FLIR VideoReportTM PC software CD-ROM, HDMI-DVI cable, HDMI-HDMI cable, Lens cap (mounted on lens), Memory card, Memory card adapter, Power supply, incl. multi-plugs, Printed Getting Started Guide, Printed important information guide, Registration card, Service & training brochure, Shoulder strap, USB cable, User documentation CD-ROM, Wi-Fi USB micro-adapter (depending on CE and FCC regulations regarding wireless equipment for your country) | |