Cart

Added to cart

Go to cart

Your order qualifies for free 2-day shipping and easy returns

Shipping & Returns Policy

  • Safety First, Each and Every Time

    Test Protective Earth (PE), electrical wiring,
    Test Charge Current Interrupt Device (CCID)
    Verify EV charger maximum current output

  • One Kit, Total Compatibility

    Designed for NACS and compatible with Type 1 — includes a compact Type 1 to NACS converter
    Comprehensive EV charger status indication with color LCD display

  • Precision in Every Measurement

    Accurately measure charging voltage and frequency with the optional FLIR DM286 digital multimeter featuring METERLiNK® connectivity

get inspection information to the people you need

FLIR METERLiNK® App

The FLIR METERLiNK® app allows you to monitor a variety of environmental and electrical conditions simultaneously with the ability to connect with up to seven FLIR compatible meters at once. METERLiNK allows you to safely capture images and monitor hazardous areas remotely and in real time. Whether you're connecting several FLIR clamp meters, digital multimeters, or any of the new METERLiNK app compatible meters, you will be able to keep tabs on key readings around your facility and easily share them with your team.

Learn More

 

FLIR-DM286-Application-Meterlink.jpg

 

Specifications
Safety Category
CAT II-300 V, IEC 61010-1
Measurement & Analysis
CP Error (E state) Simulation
Pass/Fault (CP signal short-circuited to PE)
CP State Simulation
A (Disconnected), B (Connected), C (Charging), D (Charging w/ ventilation), E (Error)
Input Type
Measuring Terminals: L1, L2/N, PE
Output for test purposes only: Max. 250 V (Single Phase), 50 / 60 Hz, CAT II 300 V, Max. 10 A
PE Error Simulation
Pass/Fault (Interruption of PE conductor)
PE Pre-Test
Pass/Fault (>50 V AC/DC between PE conductor and touch sensor)
PP State Simulation
Open, 13 A, 20 A, 32 A, 63 A
RCD/CCID Trip Test
Pass/Fault (Test RCD/CCID activation once tripped)
Voltage Phase Indication
L1, L2
Communication & Data Storage
Connector Types
NACS (Built-in), Type 1 (converter included)
Output
(Optional) DM286: CP State C / D for AC Voltage with Hz measurement
(Optional) IM75-2: CP State B for EV cable Insulation Test
Power
Battery Life
Approx. 100 hours, with alkaline batteries
Battery Type
4 × AA Alkaline batteries
General
Box Contents
EV45-NACS
Converter for Type 1
Carrying Pouch
Test Leads
4 × AA batteries
User Manual
Size (L x W x H)
237 mm × 65 mm × 56 mm
(9.33 in × 2.56 in × 2.20 in)
Weight
600 g (1.32 lbs)
Environmental & Certifications
Certifications
ETL, CE
EMC
EN61326-1
Operating Altitude
2000 m (6560 ft)
Operating Ambient Temperature and Relative Humidity (RH)
−10°C to 30°C (14°F to 86°F), <85% RH
30°C to 40°C (86°F to 104°F), <75% RH
40°C to 50°C (104°F to 122°F), <45% RH
Safety Category
CAT II-300 V, IEC 61010-1
Storage temperature and relative humidity [RH]
−20°C to 60°C (−4°F to 140°F), 0 to 80% RH (without batteries)
Warranty
Limited 3-Year Warranty

https://www.flir.com/testwarranty
Related Content
Accessories
Cases and Pouches
Media gallery
Related Documents

FLIR EV45-NACS

$799.99