Highly Sensitive, Sourceless Handheld RID

identiFINDER R440

Go to Product Support
product image

The FLIR identiFINDER R440 is a lightweight, source-less radionuclide identification device (RID) that delivers sensitive detection and fast results for routine survey or secondary screening response missions. The R440 is available with NaIL, NaI, LaBr and CLLBC detector options to respond to radiological threats from farther away, behind heavier shielding, and with better resolution than similarly-sized RIDs. The extended energy range provides neutron indication in the NaI (G) version. Its light weight makes single-handed operation easy during extended operations, while the IP67-rated enclosure is built to survive. The bold, easy-to-read interface with 360° EasyFinder™ mode expedites decision-making to keep personnel and the community safe. Hot swappable batteries facilitate continuous operation on extended missions and the ability to charge batteries outside on the instrument while the instrument is on standby ensures instant readiness in the response vehicle.

Power Through Missions

  • Higher Performance In a Rugged Form Factor

    Adding to the advanced spectroscopic algorithm and sensitivity of the original R440, the new ruggedized R440 adds optional, proven, higher resolution detection capability.

  • Ability to Power Through Missions

    Power flexibility with the new hot swappable batteries means the new R440 will go the distance and complete the mission with you.

  • Situational Awareness When You Need It

    When threat detection occurs, getting results communicated as quickly as possible is critical. The new R440 makes communications easier than ever before, no matter the method.

Specifications
System Overview
Enclosure & Protection
Aluminum housing; protection rating IP67 according to IEC 60529
Technology
Radionuclide Identification Device (RID)
Threats
Detects gamma and/or neutron radiation emitted from natural occurrences in the environment, special nuclear material, industrial, or medical material
Environmental
Operating Humidity
10 to 100% non-condensing (IP67)
Storage Temperature
-4 to 122 °F (-20 to 50 °C)
Physical Features
Dimensions (L x W x H)
≤ 4 x 10.6 x 3.7 in (10.2 x 26.9 x 9.4 cm) - with battery
Weight
≤3.2 lbs (≤1.5 kg)
Power
Battery Specs
Supplied: 2x rechargeable Li-Ion smartpacks and 1x 4x AA pack
≤6h runtime per Li-Ion smartpack; ≤4h runtime with AA battery pack.
Recharge time ≤4h when using AC; recharge >4h when using USB; run times may vary depending on operating mode.
Cold Start Time
<2 mins from cold start
Input Voltage
100-240V AC (wall adapter and USB cable supplied)
Sampling & Analysis
Library Categories
SNM, IND, MED, NORM
Nuclide Identification
Exceeds ANSI N42.34
Sample Introduction
Absorption of EM gamma (NaI) or gamma and neutron emissions (NaIL)
Time to Alarm
From a few seconds to minutes
System Interface
Communication
USB 2.0, USB OTG; Bluetooth® Class BLE 4.0 and 2.1 with EDR ≤30m range, WiFi 802.11 g/n (can be disabled at manufacture)
Data Storage
32GB internal memory
GPS [removable]
72-channel u-blox M8 engine
Software
On-board web server software
Training Requirements
<10 mins for operator; 1 day for advanced user
Technology
Energy Range [Gamma]
10 keV to 10 MeV (All detectors)
Linearization
Real-time linearization of gamma energy
Service Interval
5 year factory maintenance recommended, not required
Stabilization
Sourceless “Quantum gain” stabilization (patents pending)
Typical Resolution
≤7% FWHM at 662 keV with NaI and NaIL detector at 20 °C
≤4% FWHM at 662 keV with CLLBC detector at 20 °C
≤3% FWHM at 662 keV with LaBr detector at 20 °C
Media Gallery
Related Documents
Export Restrictions

Export Restrictions

The information contained in this page pertains to a dual use product controlled for export by the Export Administration Regulations (EAR). Diversion contrary to US law is prohibited. US Department of Commerce authorization is not required prior to export or transfer to foreign persons or parties unless otherwise prohibited.