Can't install The FLIR LabView Toolkit 3.x

When installing the LabView Toolkit I get an error that LabView Toolkit requires Windows 2000, XP or Vista and LabView must be installed. 
I have the required OS and LabView is installed.
This error is due to that an entry in the Registry is missing. This can happen when you have upgraded LabView 

The Key "HKEY_LOCAL_MACHINE\SOFTWARE\National Instruments\LabVIEW\CurrentVersion"  is either missing or does not have a value. 

The solution in this case is to add the Key in the registry and add the Path to the current LabView installation. 
Value name = Path 
Example of the Value Data: "C:\Program Files\National Instruments\LabVIEW 8.2\" 

This will allow the install program to find where to install the FLIR LabView Toolkit.