By merging industry-leading thermal imaging, thermal video analytics, and non-contact temperature measurement, the FLIR Triton™ A310F security camera offers a multi-faceted solution for perimeter intrusion detection and facility safety monitoring. The camera can measure and display actual object temperatures and generate alarms when thresholds are exceeded, even at remotely monitored facilities.

Thermal security imaging and automated safety monitoring combined
High resolution thermal imaging with analytics detects intruders and potential threats.
The Triton A310F measures object temperatures and can identify overheating equipment.
The Triton A310F generates alarms when object temperatures exceed pre-set thresholds, such as when hotspots or fires develop.

Specifiche

Ambientali
EMC EN 61000-6-2 (Immunity), EN 61000-6-3 (Emission), FCC 47 CFR Part 15 Class B (Emission)
Protezione IP 66 (IEC 60529)
Range di temperature di esercizio –25°C to +50°C (–13°F to +122°F)
Range di temperature di stoccaggio –40°C to +70°C (–40°F to +158°F)
Umidità (esercizio e stoccaggio) IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F)
Urti 5 g, 11 ms (IEC 60068-2-27)
Vibrazione 2 g (IEC 60068-2-6)
Generali
Alimentazione esterna The camera operates on 12/24 VDC, 9 W max. (allowed range: 10-30 VDC) and heaters on 24 VDC, 25 W max. In total: 34 W.
Alimentazione esterna Tipo connettore [riscaldatore] 2-pole jackable screw terminal
Contenuto Cardboard box, Infrared camera with lens and environmental, housing, FLIR Sensors Manager download card, FLIR Tools & Utilities CD-ROM, Lens cap, Printed documentation, Small accessories kit, User documentation CD-ROM
Differenza di temperatura Delta temperature between measurement functions or reference temperature
Dimensioni (L × P × A) 460 × 140 × 159 mm (18.1 × 5.5 × 6.3 in.)
Dimensioni imballo 534 x 207 x 230 mm (21.0 x 8.1 x 9.1 in.)
Formati file Standard JPEG, 16-bit measurement data included
Funzionamento con alimentazione esterna [riscaldatore] 24 VDC, 25 W max.
Materiale alloggiamento Aluminum
Montaggio su base TBA
Peso 5 kg (11.0 lb.)
Tavolozze colori Color palettes (BW, BW inv, Iron, Rain)
Tensione Allowed range 10–30 VDC
Tensione [riscaldatore] Allowed range 21-30 VDC
Tipo connettore alimentazione esterna 2-pole jackable screw terminal
Tipo sensore Focal Plane Array (FPA), uncooled microbolometer
Zoom 1–8× continuous, digital, interpolating zooming on images
Misurazioni e analisi
Accuratezza ±4°C (±7.2°F) or ±4% of reading
Area 10 boxes with max./min./average/position (7 if FLIR Sensors Manager is used)
Comandi di configurazione Date/time, Temperature°C/°F
Correzione della temperatura riflessa apparente Automatic, based on input of reflected temperature
Correzione della trasmissione atmosferica Automatic, based on inputs for distance, atmospheric temperature and relative humidity
Correzione della trasmittanza ottica Automatic, based on signals from internal sensors
Correzione emissività Variable from 0.01 to 1.0
Correzioni misurazione Global and individual object parameters
Isoterme 1 with above/below/interval
Opzione di misurazione Measurement Mask / Filter Schedule response: File sending (ftp), email (SMTP)
Ottiche esterne e Correzione finestre Automatic, based on input of optics/window transmission and temperature
Puntatore a spot 10.0
Range di temperature oggetto –20 to +120°C (–4 to +248°F) 0 to +350°C (+32 to +662°F)
Temperatura di riferimento Manually set or captured from any measurement function
PTZ
Riscaldatore automatico Clears window from ice
Integrazione di sistema
Alimentazione via Ethernet Power over Ethernet, PoE IEEE 802.3af class 0
Comunicazione Ethernet TCP/IP socket-based FLIR proprietary
Ethernet Control, result and image
Ethernet standard IEEE 802.3
Funzioni di allarme 6 automatic alarms on any selected measurement function, Digital In, Camera temperature, timer
I/O digitale, tensione d'alimentazione 12/24 VDC, max 200 mA
I/O digitale, tensione d'isolamento 500 VRMS
I/O digitale, tipo di connettore 6-pole jackable screw terminal
Ingressi digitali 2 opto-isolated, 10–30 VDC
Ingresso digitale, utilizzo Image tag (start/stop/general), Input ext. device (programmatically read)
Protocolli Ethernet Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
Streaming immagini via Ethernet 16-bit 320 × 240 pixels @ 7-8 Hz- Radiometric
Supporto di memorizzazione Built-in memory for image storage
Tipo connettore Ethernet RJ-45
Tipo connettore video Standard BNC connector
Tipo Ethernet 100 Mbps
Uscita allarme Digital Out, log, store image, file sending (ftp), email (SMTP), notification
Uscita digitale Utilizzo As function of ALARM, Output to ext. device (programmatically set)
Uscita video Composite video output, PAL and NTSC compatible
Uscite digitali 2 opto-isolated, 10–30 VDC, max 100 mA
Termocamera
Banda spettrale 7.5–13 µm
Campo visivo (FOV) 45° × 33.8° 
Costante di tempo del sensore Typical 12 ms
Distanza minima di messa a fuoco 0.20 m (0.66 ft.) 
Formato array 320 × 240
Frequenza immagine 30 Hz
Identificazione ottica Automatic
Lunghezza focale 9.66 mm (0.38 in.) 
Messa a fuoco Automatic or manual (built in motor)
numero f 1.3
Pitch sensore 25 µm
Risoluzione IR 320 × 240
Risoluzione spaziale (IFOV) 2.45 mrad 
Sensibilità termica/NETD < 0.05°C @ +30°C (+86°F) / 50 mK
Video e Registrazione
Standard video CVBS (ITU-R-BT.470 PAL/SMPTE 170M NTSC)
Streaming video via Ethernet MPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L5

Resources & Support

Brochure

FLIR A310F And A310PT Brochure

User Manual

FLIR Cyber Hardening Guide

Selection Guide

FLIR Security Product Matrix Selection Guide

Tech Note

FLIR Best Practices Guide for Perimeter Security Applications

Tech Note

FLIR Security Infographic - The Value of Using Remote Monitoring

Warranty

FLIR Fixed and Motorized Pan Tilt Thermal Security Cameras Limited Warranty