Discontinued

FLIR Triton™ A310F

Temperature-Measurement Thermal Camera

By merging industry-leading thermal imaging, thermal video analytics, and non-contact temperature measurement, the FLIR Triton™ A310F security camera offers a multi-faceted solution for perimeter intrusion detection and facility safety monitoring. The camera can measure and display actual object temperatures and generate alarms when thresholds are exceeded, even at remotely monitored facilities.

Thermal security imaging and automated safety monitoring combined
High resolution thermal imaging with analytics detects intruders and potential threats.
The Triton A310F measures object temperatures and can identify overheating equipment.
The Triton A310F generates alarms when object temperatures exceed pre-set thresholds, such as when hotspots or fires develop.

Spécifications

Spécifications environnementales
CEM EN 61000-6-2 (Immunity), EN 61000-6-3 (Emission), FCC 47 CFR Part 15 Class B (Emission)
Humidité (fonctionnement et stockage) IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F)
Plage de températures de fonctionnement –25°C to +50°C (–13°F to +122°F)
Plage de températures de stockage –40°C to +70°C (–40°F to +158°F)
Résistance aux chocs 5 g, 11 ms (IEC 60068-2-27)
Vibration 2 g (IEC 60068-2-6)
Étanchéité IP 66 (IEC 60529)
Informations générales
Alimentation externe The camera operates on 12/24 VDC, 9 W max. (allowed range: 10-30 VDC) and heaters on 24 VDC, 25 W max. In total: 34 W.
Alimentation externe [dégivrage] 24 VDC, 25 W max.
Dimensions [L x P x H] 460 × 140 × 159 mm (18.1 × 5.5 × 6.3 in.)
Format de l'emballage 534 x 207 x 230 mm (21.0 x 8.1 x 9.1 in.)
Formats de fichier Standard JPEG, 16-bit measurement data included
Liste du contenu Cardboard box, Infrared camera with lens and environmental, housing, FLIR Sensors Manager download card, FLIR Tools & Utilities CD-ROM, Lens cap, Printed documentation, Small accessories kit, User documentation CD-ROM
Matériau du boîtier Aluminum
Montage sur socle TBA
Palettes de couleurs Color palettes (BW, BW inv, Iron, Rain)
Poids 5 kg (11.0 lb.)
Tension Allowed range 10–30 VDC
Tension [dégivrage] Allowed range 21-30 VDC
Type de connecteur d'alimentation externe 2-pole jackable screw terminal
Type de connecteur d'alimentation externe (dégivrage) 2-pole jackable screw terminal
Type de détecteur Focal Plane Array (FPA), uncooled microbolometer
Zoom 1–8× continuous, digital, interpolating zooming on images
Écart de température Delta temperature between measurement functions or reference temperature
Mesure et analyse
Commandes de configuration Date/time, Temperature°C/°F
Correction liée aux optiques externes et aux fenêtres Automatic, based on input of optics/window transmission and temperature
Correction liée à la température apparente réfléchie Automatic, based on input of reflected temperature
Correction liée à la transmission atmosphérique Automatic, based on inputs for distance, atmospheric temperature and relative humidity
Correction liée à la transmission des optiques Automatic, based on signals from internal sensors
Correction liée à l’émissivité Variable from 0.01 to 1.0
Corrections de mesure Global and individual object parameters
Isotherme 1 with above/below/interval
Option de mesure Measurement Mask / Filter Schedule response: File sending (ftp), email (SMTP)
Plage de températures de l’objet –20 to +120°C (–4 to +248°F) 0 to +350°C (+32 to +662°F)
Point de mesure 10.0
Précision ±4°C (±7.2°F) or ±4% of reading
Température de référence Manually set or captured from any measurement function
Zone 10 boxes with max./min./average/position (7 if FLIR Sensors Manager is used)
PTZ
Chauffage automatique Clears window from ice
Intégration des systèmes
Alimentation Ethernet Power over Ethernet, PoE IEEE 802.3af class 0
Communication Ethernet TCP/IP socket-based FLIR proprietary
Dispositif de stockage Built-in memory for image storage
Entrées numériques 2 opto-isolated, 10–30 VDC
Ethernet Control, result and image
Flux d'images par Ethernet 16-bit 320 × 240 pixels @ 7-8 Hz- Radiometric
Fonctions d’alarme 6 automatic alarms on any selected measurement function, Digital In, Camera temperature, timer
Norme Ethernet IEEE 802.3
Objet de l'entrée numérique Image tag (start/stop/general), Input ext. device (programmatically read)
Objet de la sortie numérique As function of ALARM, Output to ext. device (programmatically set)
Protocoles Ethernet Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
Sortie d’alarme Digital Out, log, store image, file sending (ftp), email (SMTP), notification
Sortie vidéo Composite video output, PAL and NTSC compatible
Sorties numériques 2 opto-isolated, 10–30 VDC, max 100 mA
Tension d'alimentation des E/S numériques 12/24 VDC, max 200 mA
Tension d'isolation des E/S numériques 500 VRMS
Type de connecteur des E/S numériques 6-pole jackable screw terminal
Type de connecteur Ethernet RJ-45
Type de connecteur vidéo Standard BNC connector
Type de connexion Ethernet 100 Mbps
Caméra thermique
Champ de vision (CdV) 6° × 4.5° 
Constante de temps du détecteur Typical 12 ms
Distance focale 76 mm (3.0 in.) 
Distance minimale de mise au point 4 m (13.11 ft.)
Fréquence d'image 30 Hz
Gamme spectrale 7.5–13 µm
Identification de l'objectif Automatic
Mise au point Automatic or manual (built in motor)
Ouverture f 1.3
Pas du détecteur 25 µm
Résolution IR 320 × 240 pixels
Résolution spatiale (CdV instantané) 0.33 mrad 
Sensibilité thermique/NETD < 0.05°C @ +30°C (+86°F) / 50 mK
Vidéo et enregistrement
Flux vidéo via Ethernet MPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L5
Norme vidéo CVBS (ITU-R-BT.470 PAL/SMPTE 170M NTSC)

Resources & Support

Brochure

FLIR A310F And A310PT Brochure

User Manual

FLIR Cyber Hardening Guide

Selection Guide

FLIR Security Product Matrix Selection Guide

Tech Note

FLIR Best Practices Guide for Perimeter Security Applications

Tech Note

FLIR Security Infographic - The Value of Using Remote Monitoring

Warranty

FLIR Fixed and Motorized Pan Tilt Thermal Security Cameras Limited Warranty