Why do the on-camera NUCs look terrible when my SCx000 camera in in Preset Sequencing mode. They look fine in Single Preset mode.

There is an error in the configuration file that the camera loads at boot up.  This is causing the camera to apply the wrong NUC table when preset sequencing (superframing).  The camera is actually applying the table for the previous preset.  This can be corrected by loading a new systemRegisterImage.bin file to the camera.  There is a specific file for each camera type.

For SC6000 InSb (ROIC 9809/0309): use 0309_systemRegisterImage.bin.

You need to rename the file to just systemRegisterImage.bin

You can upload the file to the camera using the camera controller.  Enter the Manufacturing Mode by pressing Ctrl+Shift+M.  The password is "indigo".  On the Manufacturing page is a Camera Explorer tab.  Drag the new .bin file to the "pgm" folder.  Then disconnect and power cycle the camera. 

Currently we have only created a new file for the SC6000 InSb camera.  We will post files for the other cameras soon.

 

File Attachment(s) - seee download page

  • File Type bin0309_systemRegisterImage.bin (948 bytes)
Back to top