Discontinued

FLIR Triton™ A310F

Temperature-Measurement Thermal Camera

By merging industry-leading thermal imaging, thermal video analytics, and non-contact temperature measurement, the FLIR Triton™ A310F security camera offers a multi-faceted solution for perimeter intrusion detection and facility safety monitoring. The camera can measure and display actual object temperatures and generate alarms when thresholds are exceeded, even at remotely monitored facilities.

Thermal security imaging and automated safety monitoring combined
High resolution thermal imaging with analytics detects intruders and potential threats.
The Triton A310F measures object temperatures and can identify overheating equipment.
The Triton A310F generates alarms when object temperatures exceed pre-set thresholds, such as when hotspots or fires develop.

Technische Daten

Umgebungsfaktoren
Betriebstemperaturbereich –25°C to +50°C (–13°F to +122°F)
EMV EN 61000-6-2 (Immunity), EN 61000-6-3 (Emission), FCC 47 CFR Part 15 Class B (Emission)
Gehäuse IP 66 (IEC 60529)
Lagertemperaturbereich –40°C to +70°C (–40°F to +158°F)
Luftfeuchtigkeit (Betrieb und Lagerung) IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F)
Stoß 5 g, 11 ms (IEC 60068-2-27)
Vibrationen 2 g (IEC 60068-2-6)
Allgemeine Angaben
Abmessungen (L × B × H) 460 × 140 × 159 mm (18.1 × 5.5 × 6.3 in.)
Betrieb mit externer Stromversorgung The camera operates on 12/24 VDC, 9 W max. (allowed range: 10-30 VDC) and heaters on 24 VDC, 25 W max. In total: 34 W.
Betrieb mit externer Stromversorgung [Heizung] 24 VDC, 25 W max.
Dateiformate Standard JPEG, 16-bit measurement data included
Detektortyp Focal Plane Array (FPA), uncooled microbolometer
Differenztemperatur Delta temperature between measurement functions or reference temperature
Externe Stromversorgung, Steckverbindertyp 2-pole jackable screw terminal
Externe Stromversorgung, Steckverbindertyp [Heizung] 2-pole jackable screw terminal
Farbpaletten Color palettes (BW, BW inv, Iron, Rain)
Gehäusematerial Aluminum
Gewicht 5 kg (11.0 lb.)
Lieferumfang Cardboard box, Infrared camera with lens and environmental, housing, FLIR Sensors Manager download card, FLIR Tools & Utilities CD-ROM, Lens cap, Printed documentation, Small accessories kit, User documentation CD-ROM
Sockelbefestigung TBA
Spannung Allowed range 10–30 VDC
Spannung [Heizung] Allowed range 21-30 VDC
Verpackungsgröße 534 x 207 x 230 mm (21.0 x 8.1 x 9.1 in.)
Zoom 1–8× continuous, digital, interpolating zooming on images
Messung und Analyse
Bereich 10 boxes with max./min./average/position (7 if FLIR Sensors Manager is used)
Emissionsgrad-Korrektur Variable from 0.01 to 1.0
Genauigkeit ±4°C (±7.2°F) or ±4% of reading
Isotherm 1 with above/below/interval
Konfigurationsanweisungen Date/time, Temperature°C/°F
Korrektur des atmosphärischen Transmissionsgrads Automatic, based on inputs for distance, atmospheric temperature and relative humidity
Korrektur des Transmissionsgrads der Optik Automatic, based on signals from internal sensors
Korrektur externer Optik/Fenster Automatic, based on input of optics/window transmission and temperature
Messoption Measurement Mask / Filter Schedule response: File sending (ftp), email (SMTP)
Messpunkt 10.0
Messwertkorrekturen Global and individual object parameters
Objekttemperaturbereich –20 to +120°C (–4 to +248°F) 0 to +350°C (+32 to +662°F)
Referenztemperatur Manually set or captured from any measurement function
Äquivalenttemperaturkorrektur Automatic, based on input of reflected temperature
Schwenken/Neigen/Zoomen
Automatische Heizung Clears window from ice
Systemintegration
Alarmausgang Digital Out, log, store image, file sending (ftp), email (SMTP), notification
Alarmfunktionen 6 automatic alarms on any selected measurement function, Digital In, Camera temperature, timer
Digitalausgänge 2 opto-isolated, 10–30 VDC, max 100 mA
Digitaleingänge 2 opto-isolated, 10–30 VDC
Digitaler E/A, Steckverbindertyp 6-pole jackable screw terminal
Digitaler E/A, Trennspannung 500 VRMS
Digitaler E/A, Versorgungsspannung 12/24 VDC, max 200 mA
Ethernet Control, result and image
Ethernet, Steckverbindertyp RJ-45
Ethernet-Bildstreaming 16-bit 320 × 240 pixels @ 7-8 Hz- Radiometric
Ethernet-Stromversorgung Power over Ethernet, PoE IEEE 802.3af class 0
Ethernetkommunikation TCP/IP socket-based FLIR proprietary
Ethernetprotokolle Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
Ethernetstandard IEEE 802.3
Ethernettyp 100 Mbps
Speichermedien Built-in memory for image storage
Video-Steckverbindertyp Standard BNC connector
Videoausgang Composite video output, PAL and NTSC compatible
Zweck Digitalausgang As function of ALARM, Output to ext. device (programmatically set)
Zweck Digitaleingang Image tag (start/stop/general), Input ext. device (programmatically read)
Wärmebildkamera
Arrayformat 320 × 240
Bildfrequenz 30 Hz
Blendenzahl 1.3
Brennweite 30.38 mm (1.2 in.) 
Detektor-Zeitkonstante Typical 12 ms
Detektorraster 25 µm
Fokus Automatic or manual (built in motor)
IR-Auflösung 320 × 240
Mindestfokusabstand 1.2 m (3.93 ft.) 
Objektiverkennung Automatic
Räumliche Auflösung (IFOV) 1.36 mrad 
Sichtfeld (FOV) 25° × 18.8° 
Spektralbereich 7.5–13 µm
Thermische Empfindlichkeit / NETD < 0.05°C @ +30°C (+86°F) / 50 mK
Video und Aufzeichnung
Ethernet, Video-Streaming MPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L5
Videostandard CVBS (ITU-R-BT.470 PAL/SMPTE 170M NTSC)

Resources & Support

Brochure

FLIR A310F And A310PT Brochure

User Manual

FLIR Cyber Hardening Guide

Selection Guide

FLIR Security Product Matrix Selection Guide

Tech Note

FLIR Best Practices Guide for Perimeter Security Applications

Tech Note

FLIR Security Infographic - The Value of Using Remote Monitoring

Warranty

FLIR Fixed and Motorized Pan Tilt Thermal Security Cameras Limited Warranty