The FLIR EM54 is ideal for inspecting and troubleshooting HVAC/R ducting systems within residential, commercial, and industrial facilities. This meter can help you verify that duct inlets and outlets have the specified volumetric flow – a prerequisite to an efficient functional system. Featuring humidity, wet bulb, and dew point functions, the EM54 can measure deviations from proper relative humidity levels. Plus, the included Type-K contact temperature probe is useful to check electric motors and thermal equipment components for proper operating temperatures.

One tool provides all the environmental measurements you need
Receive high-quality data consistently, and work without interruption. Using the tripod, place the meter away from objects that may influence relative humidity measurements.
Work on a wide range of systems more efficiently using the contact temperature probe and wet bulb/dew point calculations.
Intuitively operate this simple, ergonomic meter with a backlit display, a ‘hold’ function that freezes readings, and well-marked function keys.

Specifications

Highlighted
Air Velocity (Vane Anemometer Probe) 0.4 to 30 m/s, ±3% +0.2 m/s ; 79 to 5906 ft/min, ±3% +40 ft/min; 1.4 to 108 km/h, ±3% +0.8 km/h; 0.9 to 67.2 mph, ±3% +0.4 mph; 0.8 to 58.3 knots, ±3% +0.4 knots
Air Flow 0 to 999900 CMM (0 to 999900 CFM)
Air Temperature 10 to 30°C (50 to 86°F), ±1°C (1.8°F); -30 to 9.9°C (-22 to 50°F) and 31 to 60°C (88 to 140°F), ±2°C (3.6°F)
Relative Humidity 5% to 98% ±3.5%
Dew Point -30 to 60°C (-22 to 140°F), ±3°C (4.8°F)
Wet Bulb (Calculated) -30 to 50°C (-22 to 122°F), ±3°C (4.8°F)
Measurement & Analysis
Air Temperature 10 to 30°C (50 to 86°F), ±1°C (1.8°F); -30 to 9.9°C (-22 to 50°F) and 31 to 60°C (88 to 140°F), ±2°C (3.6°F)
Air Velocity (Vane Anemometer Probe) 0.4 to 30 m/s, ±3% +0.2 m/s ; 79 to 5906 ft/min, ±3% +40 ft/min; 1.4 to 108 km/h, ±3% +0.8 km/h; 0.9 to 67.2 mph, ±3% +0.4 mph; 0.8 to 58.3 knots, ±3% +0.4 knots
Dew Point -30 to 60°C (-22 to 140°F), ±3°C (4.8°F)
Relative Humidity 5% to 98% ±3.5%
Temperature Type K thermocouple -99.9 to 99.9°C (-148 to 212°F), ±1.5% +1°C (1.8°F); 100 to 1372°C (212 to 2502°F), ±1.5% +2°C (3.6°F)
Wet Bulb (Calculated) -30 to 50°C (-22 to 122°F), ±3°C (4.8°F)
Imaging & Optical
Display Type Backlit, multifunction LCD
Dynamic Range
Sensitivity
Power
Auto Power Off (APO) Configurable from 5 to 60 min in 8 increments
Battery life 120 hours typical
Battery status indicator Low battery indication
Battery type 1x 9 V
Power
General
Air Flow 0 to 999900 CMM (0 to 999900 CFM)
Alarm
Anemometer Body Length 150 mm (5.9 in)
Anemometer Cable Length 950 mm (37.4 in)
Anemometer Vane Diameter 70 mm (2.8 in)
Dimensions
Dimensions (L x W x H) 275 × 65 × 45 mm (10.8 × 2.6 × 1.8 in)
Housing material Impact-resistant plastic
Includes Vane anemometer probe, Type-K thermocouple probe, soft carrying pouch, 9 V battery, tripod mount
System Weight
Weight 283.9 g (10 oz) with battery installed, no external probes
Environmental & Certifications
Certifications CE, RCM
Drop test 1 m (3.3 ft), not including removeable probes
Operating Temperature 0 to 50°C (32 to 122°F)
Storage Temperature Range -10 to 60°C (14 to 140°F)
Warranty Limited 3 years

Resources & Support

Quick Start Guide

EM54 Quickstart GB

User Manual

EM54 UserManual GB

User Manual

EM54 UserManual

Quick Start Guide

EM54 Quickstart

Chat

Press the chat bubble in the bottom-right corner to connect with us instantly.

(When agents available)

Phone

International Line: 

(+1) 805 392 3775

Local Number:

(+44) 0800 051 7865

Service, Repair and Calibration 

 

Europe

Service Center Contact
Phone
Request Service, Repair, or Calibration
Email Us
Belgium  +32 (0)56 363 041

Submit an RMA

Email Us

Estonia +3726063976

Submit an RMA

Email Us

Germany +49 (0) 69 95 00 900

Submit an RMA

Email Us

Italy +390294753491

Submit an RMA

Email Us

Sweden  +46 (0) 8 753 26 54

Submit an RMA

Email Us

United Arab Emirates +971 4 802 4999

Submit an RMA

Email Us

United Kingdom +44 (0)1732 220 011

Submit an RMA

Email Us

 

Americas

Service Center Contact
Phone
Request Service, Repair, or Calibration
Email Us
United States 

Toll Free: (+1) 866 477 3687

Local: (+1) 603 324 7600

Submit an RMA

Email Us

Canada 800 613 0507 Submit an RMA

Email us

South & Central America 0800 878 2486

Submit an RMA

Email us

 

Asia Pacific

Service Center Contact
Phone
Request Service, Repair, or Calibration
Email Us
Australia +61 (0) 3 9550 2800

Submit an RMA

Email Us

China +86 (0) 21-5169-7628

Submit an RMA

Email Us

India Delhi +91 11 47212002

Submit an RMA

Email Us

India Faridabad +91 (129) 431-5031/32

Submit an RMA

Email Us

Japan 81-3-6721-6648

Submit an RMA

Email Us

Singapore +65 8787 0884

Submit an RMA

Email Us

South Korea (02)565-2724

Submit an RMA

Email Us

Cart

Added to cart