A8481

Compact MWIR HD Science Camera

The A8481 and A8451 bring 1280 × 1024 HD MWIR imaging to the compact A-Series body, with four times the pixels of VGA A-Series cameras. They share their body and mounting points with the A6451, A6481, and A6700 Series, so existing fixtures and cabling carry over. The 8 µm high operating temperature (HOT) strained-layer superlattice (SLS) detector is cooled by a long-life linear cooler rated in the 27,000-hour class. The A8481 adds a motorized lens interface and a motorized 3-position filter wheel, and both cameras support a range of FLIR Precision Optics lenses. Gigabit Ethernet or CoaXPress connectivity provides complete camera control and fully radiometric capture in FLIR Research Studio Professional.

Product Overview

HD Without the Big-Body Tradeoff

The A8481 and A8451 bring HD thermal imaging to the compact A-Series form factor for the first time.

Delivering 1280 × 1024 resolution in the same proven body used throughout the A67xx family, the A84xx-Series gives researchers four times more pixels without changing optics, fixtures, software, or workflows.

The A8481 extends the platform further with a motorized filter wheel and lens interface, enabling automated optics control and broader temperature measurement capability.

The result is greater thermal detail, more measurement points, and faster scientific insight, all from a platform your team already knows. With HOT MWIR SLS technology, full radiometric recording, precision synchronization, and support for FLIR Precision Optics, the A84xx-Series helps engineers and researchers move beyond VGA limitations while keeping the simplicity of the A-Series ecosystem.

1280 × 1024
HD thermal resolution
4×
More pixels than VGA A-Series cameras
35 mK
Thermal sensitivity (NETD, Typical)
45 Hz / 60 Hz
Full-frame streaming
All in the same A-Series body. No reintegration required.
Why We Built It

HD Used to Mean a Bigger Camera

For years, moving from VGA thermal imaging to HD meant moving to a larger camera platform. New mounts. New cabling. New integration work. New validation cycles.

The A84xx-Series changes that.

Built around a 1280 × 1024 HD MWIR detector, the A8481 and A8451 bring HD thermal imaging into the same compact A-Series platform trusted by researchers and engineers around the world.

X85xx high-speed HD
Large-format high-speed platform
Range and ballistics class
A8581 large-format HD
Large-format InSb HD platform
4.6 × 5.3 × 8.9 in · 8.2 lb
A84xx Series — HD, A67xx body
Compact A67xx chassis
4.0 × 4.3 × 8.9 in · ~5 lb
Size and Integration

More Thermal Detail.
Same Footprint.

Most HD MWIR cameras require larger camera bodies and new integration efforts.

The A8481 delivers HD performance in the same compact A-Series chassis, making it simple for existing users to upgrade thermal resolution while keeping their established workflows intact.

4× More Pixels
Capture more thermal detail across the same scene without sacrificing field of view.
Zero Re-Integration
Reuse existing fixtures, mounts, cabling, optics, and software.
Compact Design
Deploy HD imaging in space-constrained labs, test cells, and research environments.
A8581 · large-format body
4.6 × 5.3 in front face · 8.2 lb



A8481 · compact A67xx body
4.0 × 4.3 in front face · ~5 lb
A Natural Upgrade Path

Four Times the Pixels.
Same Workflow.

The A8481 was designed as a natural upgrade path for A-Series users.
Keep
• Existing FLIR Precision Optics
• Existing mounts and fixtures
• Existing software environment
• Existing analysis workflows
• Existing automation infrastructure
The HD array is nearly the same physical size (10.2 mm vs 9.6 mm across) - so on the same focal length you keep a comparable field of view, now sampled roughly twice as finely. Or window in and trade pixels for speed.
 
640 × 512
327,680 pixels · 15 µm
→
 
1280 × 1024
1,310,720 pixels · 8 µm
 
Applications

One Camera. Multiple
Research Environments.

Designed for Scientific Discovery and Test Validation
Electronics & PCB Analysis
Identify component-level hot spots while maintaining visibility of the entire board.
Battery Research
Capture temperature variations across cells, modules, and packs with greater spatial detail.
Materials & Mechanical Testing
Measure thermal behavior across larger samples while resolving smaller features.
NDT & Inspection
Detect and characterize defects with improved image density and thermal clarity.
Combustion & Propulsion
Study thermal structures in flames, exhaust streams, and high-temperature events.
Academic Research
A flexible platform that supports multiple projects, laboratories, and departments.
Optics

One mount, three optics families

More Pixels on Target
The A8481 supports the full ecosystem of FLIR Precision Optics, allowing researchers to optimize spatial resolution for nearly any application.
Manual Focus Lenses
17 mm to 200 mm options
Motorized Focus Lenses
Control focus directly within Research Studio
Microscope Optics
Capture thermal detail down to 1.6 µm/pixel
Macro Imaging
Analyze small components and materials with exceptional detail
Measurement and Control

Measurement-Grade
Thermal Data

The A8481 combines HD imagery with the measurement accuracy and control required for demanding R&D environments.
Key Capabilities
• Fully radiometric data capture
• Precision trigger and synchronization I/O
• GigE Vision and GenICam compatibility
• CoaXPress support
• Windowed frame rates up to 13,733 Hz
• Motorized filter wheel for expanded measurement ranges
• Radiometric .ATS recording
Software

Powered by FLIR
Research Studio

Acquire, record, analyze, and share thermal data through the same workflow trusted across the FLIR science camera portfolio.
Connect
Connect cameras quickly via GigE or CoaXPress.
View
Visualize HD thermal data in real time.
Record
Capture fully radiometric datasets.
Analyze
Generate plots, profiles, statistics, and reports.
• Maximize measurement pixels with manual, microscope, and macro FLIR Precision Optics lenses, plus motor-focus lenses on the A8481
• Extend the measurable temperature range with the motorized 3-position filter wheel on the A8481
• Lock capture to your test with precision triggering and sync I/O
• Analyze and record 1280 × 1024 (1.3 MP) HD thermal imagery, fully radiometric
• Detect small thermal differences with 35 mK NETD (typical)
• Inspect small components up close with optional 1× and 3× microscope lenses
• Stream fully radiometric data at 45 Hz over Gigabit Ethernet or 60 Hz over CoaXPress
• Acquire and analyze in Research Studio's Connect → View → Record → Analyze workflow
• Work in the operating system and language your team prefers

사양

강조 표시됨
적외선 해상도 1280 × 1024 HD
스펙트럼 범위 3.4 - 5.1 µm
탐지기 유형 HOT MWIR SLS
F-값 f/2.5
동작 범위 14-bit
최대 프레임률 Frame rate (full): 45 Hz GigE, 60 Hz CXP
Frame rate (windowed): up to 13,733 Hz (32 × 4)
최대 프레임률 [화면 최소화 시] up to 13,733 Hz (32 × 4)
노출 시간 Minimum: 480 ns to ~full frame
표준 온도 범위 -20°C to 350°C (-4°F to 662°F), -10°C for microscopes
선택 가능 온도 범위 45°C to 600°C (113°F to 1112°F) (ND1)
250°C to 2000°C (482°F to 362°F) (ND2)
500°C to 3000°C (932°F to 5432°F) (ND3)
이미징 및 광학
F-값 f/2.5
노출 시간 Minimum: 480 ns to ~full frame
동영상 모드 SDI: 720p @ 50/59.9, 1080p @ 25/29.9
동영상 표준 SDI
동작 범위 14-bit
라디오메트릭(radiometric 적외선 동영상 스트리밍 GigE Vision / CoaXPress
렌즈 인터페이스 FLIR Precision Optics bayonet
사용 가능한 렌즈 Manual (3-5 μm): 17 mm, 25 mm, 50 mm, 100 mm, 200 mm, 50 mm Macro
Motorized (3-5 μm): 17 mm, 25 mm, 50 mm, 100 mm, 200 mm
서브 윈도우 모드 Flexible windowing down to 16 × 4 (steps of 16 columns, 4 rows)
센서 냉각 Linear, closed-cycle (27,000 h)
스펙트럼 범위 3.4 - 5.1 µm
열 감도_NETD[일반] 35 mK NETD (typical)
운전성 99.5%
이미지 타임 스탬프 Yes
적외선 해상도 1280 × 1024 HD
최대 프레임률 Frame rate (full): 45 Hz GigE, 60 Hz CXP
Frame rate (windowed): up to 13,733 Hz (32 × 4)
최대 프레임률 [화면 최소화 시] up to 13,733 Hz (32 × 4)
클로즈_업 렌즈_현미경 1x, 3x
탐지기 유형 HOT MWIR SLS
판독 모드 Asynchronous integrate while read / Asynchronous integrate then read
판독 형식 Snapshot
화소 클럭 50 MHz
측정 및 분석
대상 온도 범위 -20°C to 3000°C (-4°F to 5432°F)
선택 가능 온도 범위 45°C to 600°C (113°F to 1112°F) (ND1)
250°C to 2000°C (482°F to 362°F) (ND2)
500°C to 3000°C (932°F to 5432°F) (ND3)
자동 게인 (Gain) 제어 Manual, Linear, Plateau equalization, DDE
정확도 2°C or ±2% of reading
표준 온도 범위 -20°C to 350°C (-4°F to 662°F), -10°C for microscopes
통신 및 데이터 저장 공간
동기화 모드 Sync in / Sync out
제어 및 조종 GigE, CXP, RS-232
일반
무게 [렌즈 제외] 2.3 kg (5 lbs)
크기 [L × W × H] 226 × 102 × 109 mm (8.9 × 4.0 × 4.3 in.)
전력
전원 Nominal voltage is 24 V DC (ranging from 20 to 28 V); continuous current is 1.4 A,

액세서리

Export Restrictions

The information contained in this page pertains to products that may be subject to the International Traffic in Arms Regulations (ITAR) (22 C.F.R. Sections 120-130) or the Export Administration Regulations (EAR) (15 C.F.R. Sections 730-774) depending upon specifications for the final product; jurisdiction and classification will be provided upon request.