단종

intelliRock III Reader

Concrete Strength and Temperature Profiling System

The intelliRock III reader provides connectivity to loggers in the field so critical decisions can be made at the touch of a button. You can easily activate loggers to start tracking key data points during concrete curing. It features a built–in thermal imager for temperature profiling and onsite problem detection. Use the reader to input important notes and jobsite or location information specific to that logger.

BUILD FASTER, STRIP FORMS EARLIER, OPTIMIZE POST-TENSION WORK
Use the built-in 160 × 120 resolution FLIR thermal imager to identify surface temperature issues and monitor insulation performance or cylinder curing conditions.
View stored temperature and strength data and record important notes in order to keep the project on track
Cut the time spent using equipment rentals, and reduce cement and labor costs

사양

이미징 및 광학
카메라 160 × 120 resolution thermal imager
측정 및 분석
과부하 선량률 범위 10 mSv/h to 500 mSv/h (1 rem/h to 50 rem/h)
교정 곡선 Holds 5 calibration curves for strength conversions
기록기 데이터 저장 999 logger downloads
만기 Yes
시간 정확도 1 minute per month
시점 Yes
온도 Yes
온도 정확도 ±1°C, -20 to 80°C (4 to 176°F), ±2°C, 80 to 99°C (176 to 210.2°F)
온도 측정률 1 minute (resolution for min/max)
온도 해상도 1°C (1.8°F)
최대 온도 측정 범위 -20°C to 125°C (23°F to 257°F)
최대 저장 시간 및 온도 85°C (185°F) for 5 years
통신 및 데이터 저장 공간
PC 인터페이스 USB and Bluetooth
사용자 인터페이스
비고 8+ job site names and logger locations
이벤트 6+ max and min temperature
전력
배터리 Rechargeable
환경 및 인증
일반 리더 사양_작동 온도 -5° to 50°C (23° to 122°F)
작동 온도 -20°C to 99°C (-4°F to 210.2°F)

Export Restrictions

The information contained in this page pertains to products that may be subject to the International Traffic in Arms Regulations (ITAR) (22 C.F.R. Sections 120-130) or the Export Administration Regulations (EAR) (15 C.F.R. Sections 730-774) depending upon specifications for the final product; jurisdiction and classification will be provided upon request.