Discontinued

FLIR Triton™ A310F

Temperature-Measurement Thermal Camera

By merging industry-leading thermal imaging, thermal video analytics, and non-contact temperature measurement, the FLIR Triton™ A310F security camera offers a multi-faceted solution for perimeter intrusion detection and facility safety monitoring. The camera can measure and display actual object temperatures and generate alarms when thresholds are exceeded, even at remotely monitored facilities.

Thermal security imaging and automated safety monitoring combined
High resolution thermal imaging with analytics detects intruders and potential threats.
The Triton A310F measures object temperatures and can identify overheating equipment.
The Triton A310F generates alarms when object temperatures exceed pre-set thresholds, such as when hotspots or fires develop.

Especificaciones

Características medioambientales
EMC EN 61000-6-2 (Immunity), EN 61000-6-3 (Emission), FCC 47 CFR Part 15 Class B (Emission)
Golpes 5 g, 11 ms (IEC 60068-2-27)
Humedad (operativa y de almacenamiento) IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F)
Protección IP 66 (IEC 60529)
Rango de temperatura de almacenamiento –40°C to +70°C (–40°F to +158°F)
Rango de temperatura operativa –25°C to +50°C (–13°F to +122°F)
Vibración 2 g (IEC 60068-2-6)
General
Diferencia de temperatura Delta temperature between measurement functions or reference temperature
Formatos de archivo Standard JPEG, 16-bit measurement data included
Funcionamiento con alimentación externa The camera operates on 12/24 VDC, 9 W max. (allowed range: 10-30 VDC) and heaters on 24 VDC, 25 W max. In total: 34 W.
Funcionamiento con alimentación externa [calentador] 24 VDC, 25 W max.
Lista de contenido Cardboard box, Infrared camera with lens and environmental, housing, FLIR Sensors Manager download card, FLIR Tools & Utilities CD-ROM, Lens cap, Printed documentation, Small accessories kit, User documentation CD-ROM
Material de la carcasa Aluminum
Montaje sobre base TBA
Paletas de colores Color palettes (BW, BW inv, Iron, Rain)
Peso 5 kg (11.0 lb.)
Tamaño (L. × An. × Al.) 460 × 140 × 159 mm (18.1 × 5.5 × 6.3 in.)
Tamaño del embalaje 534 x 207 x 230 mm (21.0 x 8.1 x 9.1 in.)
Tipo de conector de alimentación externa 2-pole jackable screw terminal
Tipo de conector de alimentación externa [calentador] 2-pole jackable screw terminal
Tipo de detector Focal Plane Array (FPA), uncooled microbolometer
Voltaje Allowed range 10–30 VDC
Voltaje [calentador] Allowed range 21-30 VDC
Zoom 1–8× continuous, digital, interpolating zooming on images
Medición y análisis
Comandos de configuración Date/time, Temperature°C/°F
Correcciones de medición Global and individual object parameters
Corrección de emisividad Variable from 0.01 to 1.0
Corrección de temperatura aparente reflejada Automatic, based on input of reflected temperature
Corrección de transmisión atmosférica Automatic, based on inputs for distance, atmospheric temperature and relative humidity
Corrección de transmisión óptica Automatic, based on signals from internal sensors
Isotérmico 1 with above/below/interval
Medidor puntual 10.0
Opción de medición Measurement Mask / Filter Schedule response: File sending (ftp), email (SMTP)
Precisión ±4°C (±7.2°F) or ±4% of reading
Rango de temperatura del objeto –20 to +120°C (–4 to +248°F) 0 to +350°C (+32 to +662°F)
Temperatura de referencia Manually set or captured from any measurement function
Área 10 boxes with max./min./average/position (7 if FLIR Sensors Manager is used)
Óptica externa y corrección de ventanas Automatic, based on input of optics/window transmission and temperature
PTZ
Calentador automático Clears window from ice
Integración de sistema
Alimentación por Ethernet Power over Ethernet, PoE IEEE 802.3af class 0
Comunicación Ethernet TCP/IP socket-based FLIR proprietary
Entrada digital, propósito Image tag (start/stop/general), Input ext. device (programmatically read)
Entrada/salida digital, tipo de conector 6-pole jackable screw terminal
Entrada/salida digital, voltaje de aislamiento 500 VRMS
Entrada/salida digital, voltaje de alimentación 12/24 VDC, max 200 mA
Entradas digitales 2 opto-isolated, 10–30 VDC
Estándar Ethernet IEEE 802.3
Ethernet Control, result and image
Funciones de alarma 6 automatic alarms on any selected measurement function, Digital In, Camera temperature, timer
Protocolos de Ethernet Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
Salida de alarma Digital Out, log, store image, file sending (ftp), email (SMTP), notification
Salida de vídeo Composite video output, PAL and NTSC compatible
Salida digital, propósito As function of ALARM, Output to ext. device (programmatically set)
Salidas digitales 2 opto-isolated, 10–30 VDC, max 100 mA
Soporte de almacenamiento Built-in memory for image storage
Tipo de conector de vídeo Standard BNC connector
Tipo de conector Ethernet RJ-45
Tipo de Ethernet 100 Mbps
Transmisión de imágenes por Ethernet 16-bit 320 × 240 pixels @ 7-8 Hz- Radiometric
Cámara térmica
Campo de visión (FOV) 45° × 33.8° 
Constante de tiempo del detector Typical 12 ms
Distancia focal mínima 0.20 m (0.66 ft.) 
Enfoque Automatic or manual (built in motor)
Formato en matriz 320 × 240
Frecuencia de la imagen 30 Hz
Identificación de la lente Automatic
Longitud focal 9.66 mm (0.38 in.) 
Número F 1.3
Paso del detector 25 µm
Rango espectral 7.5–13 µm
Resolución de IR 320 × 240
Resolución espacial (IFOV) 2.45 mrad 
Sensibilidad térmica/NETD < 0.05°C @ +30°C (+86°F) / 50 mK
Vídeo y grabación
Estándar de vídeo CVBS (ITU-R-BT.470 PAL/SMPTE 170M NTSC)
Transmisión de vídeo por Ethernet MPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L5

Resources & Support

Brochure

FLIR A310F And A310PT Brochure

User Manual

FLIR Cyber Hardening Guide

Selection Guide

FLIR Security Product Matrix Selection Guide

Tech Note

FLIR Best Practices Guide for Perimeter Security Applications

Tech Note

FLIR Security Infographic - The Value of Using Remote Monitoring

Warranty

FLIR Fixed and Motorized Pan Tilt Thermal Security Cameras Limited Warranty