The DM66 digital multimeter is ideal for automation field service or electronics technicians, providing a comprehensive feature set including low impedance (LoZ) mode, frequency, diode, capacitance, and a Type K thermocouple input for temperature measurement. The multimeter combines rich features, precise measurements, and quality construction into a tool of exceptional value. Easy to use and built to last, the DM66 offers long-term stability for everyday use.

$149.99
Buy Now Request Info

Your DMM for automation field service and electronics

  • All the Features You Need

    Provides rich features for various electrical applications including AC/DC measurement, safe non-contact voltage detection, a flashing backlight, and audible indicator.

  • Quick, Efficient Testing and Troubleshooting

    Navigate the meter’s on-screen menu system easily, and operate one-handed thanks to the compact design and easy-to-access buttons.

  • High Quality, Tough, Reliable

    The DM66 is drop-tested, IP40 rated, and has a CAT IV-300V, CAT III-600V safety category rating to ensure safe and accurate operation.

Specifications
Overview
Auto Power Off
Yes
Warranty
Limited lifetime warranty
Environmental
Drop test
2 m
IP Rating
IP40
Measurement & Analysis
Capacitance
Range: Basic Accuracy: 200.0 nF ±1.5% 200.0 µF ±1.5% 10 mF ±4.5% 10.00 mF ±5.0%
Diode Test
Range: 3.000 V Basic Accuracy: ±0.9%
Frequency Range
Range: 99.99 kHz Basic Accuracy: ±1.0%
Resistance
Range: Basic Accuracy: 600.0 kΩ ±0.5% 6.00 MΩ ±0.3% 60.00 MΩ ±0.9%
Thermocouple
–40 to 752.0°F DMM ± (1.0% + 3°F), –40 to 400°C DMM ± (1.0% + 1.5°C)
VFD AC Voltage
Range: 600.0 V RMS Basic Accuracy: ±1.0%
Continuity check
Between 30 Ω and 480 Ω
Power
AC/DC LoZ V
Range: 600.0 V Basic Accuracy: ±2.0%
AC/DC mAmps
Range: 600.0 mA Basic Accuracy: ±1.0% / ±0.7%
AC/DC microAmps
Range: 6000 µA Basic Accuracy: ±1.5% / ±1.0%
AC/DC mVolt
Range: 600.0 mV Basic Accuracy: ±1% / ±0.4%
AC/DC Voltage
Range: 600.0 V Basic Accuracy: ±1.0% / ±0.4%
AC/DC Amps
Range: 10.00 A Basic Accuracy: ±1.5% / ±1.0%