FLIR DM62
Support Center

FLIR DM62

Go to Product Details Page

For Support
Please call 1-800-GO-INFRA (464-6372) or 1-603-324-7600 or submit a ticket.

For Service
Call 1-866-354-7911 or submit RMA.

Help others by sharing your experience with our products.

Overview:
Warranty & RMA

Test & Measurement Warranty

Learn more
Resources:
Digital Multimeter Selection Guide
Download
FLIR DM62 & DM66 Datasheet
Download
FLIR Test & Measurement Limited Three Year Warranty
Download
FLIR Digital Multimeter Guide
Download
Specifications
Overview
Warranty
Limited 3-Year
Environmental
Drop test
2 m
IP Rating
IP40
Measurement & Analysis
AC/DC mAmps
Range: 600.0 mA Basic Accuracy: ±1.0% / ±0.7%
AC/DC microAmps
Range: 6000 µA Basic Accuracy: ±1.5% / ±1.0%
AC/DC mVolt
Range: 600.0 mV Basic Accuracy: ±1% / ±0.4%
AC/DC Voltage
Range: 600.0 V Basic Accuracy: ±1.0% / ±0.4%
Diode Test
Range: 3.000 V Basic Accuracy: ±0.9%
Resistance
Range: Basic Accuracy: 600.0 kΩ ±0.5% 6.00 MΩ ±0.3% 60.00 MΩ ±0.9%
VFD AC Voltage
Range: 600.0 V RMS Basic Accuracy: ±1.0%
AC/DC Amps
Range: 10.00 A Basic Accuracy: ±1.5% / ±1.0%
Continuity check
Between 30 Ω and 480 Ω
True RMS
Yes
Meter Data
Auto Power Off
Yes
Power
Battery
3 AA batteries; optional TA04 Li-Poly rechargeable battery