Support Center
FLIR DM166
For Support
Please
call 1-800-GO-INFRA (464-6372)
or 1-603-324-7600
or
submit a ticket.
For Service
Call 1-866-354-7911
or
submit RMA.
Overview:
Resources:
Specifications
Overview
- IR Resolution
- 60 × 80 pixels (4,800 pixels)
- Warranty
- 10 yrs on product and detector
Environmental
- Drop test
- 3 m
- IP Rating
- IP40
Imaging & Optical
- Focus
- Fixed
- Thermal image palettes
- Rainbow, iron, gray scale
Measurement & Analysis
- AC/DC mAmps
- Range: 600.0 mA Basic Accuracy: ±1.0% / ±0.7%
- AC/DC microAmps
- Range: 4000 µA Basic Accuracy: ±1.5%
- AC/DC mVolt
- Range: 600.0 mV Basic Accuracy: ±1% / ±0.5%
- AC/DC Voltage
- Range: 600.0 V Basic Accuracy: ±0.7% / ±0.5%
- Capacitance
- Range: Basic Accuracy: 200.0 nF ±1.5% 200.0 µF ±1.5% 2.000 mF ±2.0% 10.00 mF ±5.0%
- Diode Test
- Range: 3.000 V Basic Accuracy: ±0.9%
- Frequency Range
- Range: 99.99 kHz Basic Accuracy: ±1.0%
- Resistance
- Range: Basic Accuracy: 600.0 Ω ±0.3% 600.0 kΩ ±0.5% 6.000 MΩ ±0.9% 60.00 MΩ ±1.5%
- Temperature Range
- –10 to 150°C (14 to 302°F)
- Thermocouple
- –40 to 752.0°F DMM ± (1.0% + 3°F), –40 to 400°C DMM ± (1.0% + 1.5°C)
- VFD AC Voltage
- Range: 600.0 V RMS Basic Accuracy: ±1.0%
- AC/DC Amps
- Range: 10.00 A Basic Accuracy: ±1.0% / ±0.7%
- Continuity check
- Between 30 Ω and 480 Ω
- True RMS
- Yes
Meter Data
- Auto Power Off
- Yes
Power
- Battery
- 3 AA batteries; optional TA04 Li-Poly rechargeable battery