Specifications
System Overview
Technology
Radionuclide identification device (RID)
Battery Specification
Internal Li-ion cells; additional user-selectable external battery (1 each 16650 Li-ion or 2 each CR123); hot-swappable
Environmental
Operating Humidity
10 to 93%, non-condensing
Operating Temperature
-22 to 140 °F (-30 to 60 °C)
Storage Temperature
14 to 95 °F (-10 to 35 °C)
Physical Features
Enclosure & Protection
Injection molded housing with overmold; rating IP67 according to IEC 60529
Power
Battery Specs
Internal Li-ion cells; additional user-selectable external battery (1 each 16650 Li-ion or 2 each CR123); hot-swappable
Cold Start Time
<30 seconds from cold start
Input Voltage
100-240 AC (wall adapter and USB-C cable supplied)
Sampling & Analysis
Nuclide Identification
According to ANSI N42.34
Sample Introduction
Absorption of EM gamma and neutron emissions
Threats
Detects neutron and gamma radiation emitted from natural occurrences in the environment, special nuclear material, industrial, or medical material
Library Categories
SNM, IND, MED, NORM
Time to Identification
From a few seconds to a few minutes
System Interface
Communication
USB-C (2x), Bluetooth (BLE 5.0)
Data Storage
8 GB internal memory
Software
Onboard webserver software
Data File Format
According to ANSI N42.42
Technology
Energy Range [Gamma]
25 keV - 3 MeV
Overload Dose Rate Range
50 uSv/h - 10 mSv/h
Service Interval
5-year factory maintenance
Stabilization
Sourceless Gain Stabilization
Typical Resolution
≤ 7% FWHM at 662 keV (20°C)
Linearization
Real time linearization of gamma energy
Gamma Spectrum Length
1024 channels
Gamma Sensitivity [Cs–137]
1610 cps/µSv/h